Rinnai EfficiencyHD250 Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Ohřívače vody a bojlery Rinnai EfficiencyHD250. Rinnai EfficiencyHD250 Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Continuous ow

Specication guideContinuous owwater heating

Strany 2 - Important

10 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Specifying commercial solutionsRinnai Infinity HD/EF units, manifolded units (j

Strany 3

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 11It is important when designing central water heating systems that they are siz

Strany 4 - Leaders in continuous ow

12 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Fault indicationIn multiple unit installations it is important to know if a wa

Strany 5 - What is continuous ow?

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 13Manifold electronic control system (MECS)Infinity units can be manifolded toget

Strany 6 - Continuous ow summary table

14 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Circulating ring mains with Rinnai InnitiesHot water immediately when you tur

Strany 7

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 15Positioning continuous ow unitsIn order to provide safe and effective water he

Strany 8

16 | Rinnai Continuous Flow Water Heating Specication Guide 02-13General ue clearances - external modelsThe following diagram has been provide

Strany 9

Rinnai continuous ow water heatersProduct specication pages

Strany 10 - Continuous flow worked example

18 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity VT specication summaryRinnai Infinity VT external codesGas Type

Strany 11 - Sizing example

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 19Rinnai Innity VT dimensions (mm)BDCMAEFJLHGIKONPVT16 VR1620WGVT20 VR2024WGVT2

Strany 12 - Off 65 ºC

This guide has been written to help you select and order the right Rinnai continuous flow water heater, associated components, and accessories for the

Strany 13 - REUMSBMB

20 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity VT accessories summaryCompact Controller EntryControllersMCNo.

Strany 14 - Expansion

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 21ControllersA maximum of four water controllers can be fitted, and any combinati

Strany 15 - 600 mm min

22 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity HD specication summaryRinnai Infinity HD codesGas Type HD200 ex

Strany 16

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 23Rinnai Innity HD dimensions (mm)BDCMAEFJLHGIKONPHD200 external VRM2632WCHDi20

Strany 17 - Product

24 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity HD accessories summaryCompact Controller EntryControllersMCNo.

Strany 18

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 25ControllersFor domestic applications, a maximum of four water controllers can

Strany 19

26 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity EF specication summaryRinnai Infinity EF codesGas Type EF24 ext

Strany 20 - Water Heater

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 27Rinnai Innity EF dimensions (mm)BDCMAEFJLHGIKONPEF24 external K2430WGEFi250 i

Strany 21

28 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity EF accessories summaryCompact Controller EntryControllersMCNo.

Strany 22

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 29ControllersFor domestic applications, a maximum of four water controllers can

Strany 23

cnt:Leaders in continuous flow ...4What is continuous flow? ...5Continuous flo

Strany 24

30 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity internal ueingThe Rinnai Infinity internal flueing system is hig

Strany 25

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 311234Direct flueingFor installations where the internal Rinnai continuous flow un

Strany 26

32 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity internal ue congurationsDirect flueing using FFSSKITFor instal

Strany 27

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 33Vertical straight flueingFor installations where the Rinnai Infinity needs to be

Strany 28

34 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity internal ueing components953 ± 5 mm483 ± 5 mmStainless steel i

Strany 29

Rinnai continuous ow water heatersAccessories

Strany 30 - Roof cowl

36 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity water controllers83 90 120 20 BC-100V971952283 128 120 20(mm)Co

Strany 31

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 37Maximum number of controllersFor domestic applications, a maximum of four wate

Strany 32 - Condensate direcon

38 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity composite recess boxSpecification summaryCodeR1406DescriptionThe

Strany 33 - To sanitary waste

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 39Rinnai Innity metal recess boxSpecification summaryCodesR1405R1407Refer '

Strany 34 - 120 ± 5 mm

4 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Leaders in continuous owWhen you turn on a tap, you want water at the right te

Strany 35 - Accessories

40 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity pipe coversWDH1H2Specification summaryCodesR1385R1402SCR1408R140

Strany 36 - Specification summary

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 41Rinnai Innity security bracketSecurity bracketWater heater bracketSecurity br

Strany 37

42 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity sideways ue diverterSpecification summaryCodes - FDS16 Suitable

Strany 38

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 43Rinnai Innity upwards ue diverterSpecification summaryCodes - FDU16 Suitable

Strany 39 - 514 mm (R1407)

44 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity HD error switchSpecification summaryCodeR1070DescriptionThe Rinn

Strany 40 - Rinnai Innity pipe covers

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 45Rinnai Innity EZ connect cableSpecification summaryCodeREUEZCDescriptionThe in

Strany 41

46 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Rinnai Innity manifoldingSpecification summaryCodes - REUMSBM Internal (connec

Strany 42

Rinnai continuous ow water heatersAppendices

Strany 43

48 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Appendix 1: Limited warrantyThis warranty is applicable to all Rinnai continuo

Strany 44

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 49General warranty termsRinnai reserves the right to make modifications and chang

Strany 45

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 5What is continuous ow?It is exactly that—a continuous flow hot water system. Un

Strany 46 - Rinnai Innity manifolding

50 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Water qualityWater quality outside the limits, as set down below, will void th

Strany 47 - Appendices

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 51Appendix 2: Water ow and gas usageWhen calculating the model of Rinnai Infinit

Strany 48 - Appendix 1: Limited warranty

52 | Rinnai Continuous Flow Water Heating Specication Guide 02-13HD range, temperature preset to 55 °C or less (mixed water)5 °C temperature ri

Strany 49

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 53HD range, temperature preset to 75 °C (unmixed water)5 °C temperature rise 10

Strany 50

54 | Rinnai Continuous Flow Water Heating Specication Guide 02-13EF range, temperature preset to 55 °C or less (mixed water)5 °C temperature ri

Strany 51

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 55EF range, temperature preset to 75 °C (unmixed water)5 °C temperature rise 10

Strany 52

56 | Rinnai Continuous Flow Water Heating Specication Guide 02-13VT range, temperature preset to 55 °C or less (mixed water)5 °C temperature ri

Strany 53

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 57Appendix 3: Commercial sizing guidelinesSizing guidelines for commercial appli

Strany 54

58 | Rinnai Continuous Flow Water Heating Specication Guide 02-13We often get asked about how long a gas bottle will last when running a gas ap

Strany 55

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 59Appendix 5: Gas boosted solarIn New Zealand, solar systems will need boosting

Strany 56

6 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Continuous ow summary tableModel Mounting positionApplication suitability Ene

Strany 57

Rinnai.co.nz Experience our innovation 0800 746 624http://www.youtube.com/rinnainz

Strany 58

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 7Model selection - domestic applicationsWhen specifying residential hot water ap

Strany 59 - Appendix 5: Gas boosted solar

8 | Rinnai Continuous Flow Water Heating Specication Guide 02-13Product selector - domestic applicationsYour budget, size of house, number of o

Strany 60 - Experience our innovation

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 9Rinnai Innity digital water controllersWith a Rinnai Infinity digital controlle