Rinnai RC98I Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bojler Rinnai RC98I. Rinnai RC98I User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 64
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
Operation and Installation Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents .................... 2
Consumer Safety Information .. 4
Operating Instructions .............. 5
Maintenance ............................ 11
Error Codes ............................. 12
Installation Instructions ............ 16
Consumer Support ................... 41
French Version ........................ 43
Tankless Water Heater
Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)
ANS Z21.10.3
CSA 4.3
FOR INDOOR APPLICATIONS ONLY
RC80i .................. REU-KA2530FFUD-US
RC98i .................. REU-KA3237FFUD-US
FOR OUTDOOR APPLICATIONS ONLY
RC80e ................. REU-KA2530WD-US
RC98e ................. REU-KA3237WD-US
Zobrazit stránku 0
1 2 3 4 5 6 ... 63 64

Shrnutí obsahu

Strany 1 - Tankless Water Heater

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

Strany 2 - Table of Contents

10 Manual - Rinnai Condensing Water Heaters Setting Controller to Mute To eliminate the beeps when keys are pressed or to turn the

Strany 3 - Specifications

Manual - Rinnai Condensing Water Heaters 11 WARNING Turn off the electrical power supply, the manual gas valve and the manual water control v

Strany 4 - Consumer Safety Information

12 Manual - Rinnai Condensing Water Heaters Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fault

Strany 5 - Operating Instructions

Manual - Rinnai Condensing Water Heaters 13 Code Fault Remedy 16 Over Temperature Warning Check for restrictions in air flow around unit and ven

Strany 6

14 Manual - Rinnai Condensing Water Heaters Trouble Shooting for Common Issues I don’t have any hot water when I open the tap. Mak

Strany 7

Manual - Rinnai Condensing Water Heaters 15 Water HeaterPressure Relief Valve3/4" Ball Valve3/4" UnionCheck ValveSPressure RegulatorCirc

Strany 8 - (Voice Prompt)

16 Manual - Rinnai Condensing Water Heaters Only properly trained and qualified installers should install this appliance. The warranty may be voide

Strany 9

Manual - Rinnai Condensing Water Heaters 17 Clearances from Appliance 1. Identify the installation location and confirm that the

Strany 10

18 Manual - Rinnai Condensing Water Heaters Gas Piping General Instructions • A manual gas control valve must be placed in th

Strany 11 -

Manual - Rinnai Condensing Water Heaters 19 Pipe Sizing Procedure - Example Gas Piping The gas supply must be capable of han

Strany 12 - Error Codes

2 Manual - Rinnai Condensing Water Heaters Specifications ... 3 Consumer Safety Information Safe

Strany 13 - Code Fault Remedy

20 Manual - Rinnai Condensing Water Heaters Isolation Valves and Pressure Relief Valve Water Piping The isolation valves provi

Strany 14

Manual - Rinnai Condensing Water Heaters 21 The freeze protection features include electrical heating elements. Freeze protection may be disabled

Strany 15

22 Manual - Rinnai Condensing Water Heaters If the water heater is not going to be used during a period of possible freezing weather, it is recommen

Strany 16 - Installation Instructions

Manual - Rinnai Condensing Water Heaters 23 Recommended Piping for Basic Installation GasSupply3/4"ColdWaterSupplyLine3/4"

Strany 17

24 Manual - Rinnai Condensing Water Heaters Recommended Piping for Circulation Systems Pressure Relief Valve3/4" Ball Valve3/4"

Strany 18

Manual - Rinnai Condensing Water Heaters 25 Venting Instructions • This water heater is a direct vent water heater and therefo

Strany 19

26 Manual - Rinnai Condensing Water Heaters Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual lengt

Strany 20

Manual - Rinnai Condensing Water Heaters 27 Flue Terminal Clearances (ANS Z21.10.3, CSA 4.3) INSIDECORNER DETAI LFIXEDCLOSEDOPERABL

Strany 21 - Pressure Relief Valve

28 Manual - Rinnai Condensing Water Heaters 24"V Additional Clearances - Vent Terminal (RC80i, RC98i) Local codes supersede these cle

Strany 22

Manual - Rinnai Condensing Water Heaters 29 2"36"12"INSIDECORNER Additional Clearances (RC80e, RC98e) Local codes super

Strany 23 - Refer to the Condensate

Manual - Rinnai Condensing Water Heaters 3 Specifications Rinnai is continually updating and improving products. Therefore, specifications are su

Strany 24

30 Manual - Rinnai Condensing Water Heaters Flue Installation (RC80i, RC98i) Secure the first vent component to the water heater with

Strany 25

Manual - Rinnai Condensing Water Heaters 31 High Altitude Installations 0-2000 ft (0-610 m) 2001-5200 ft (610-1585 m) 5201-7700

Strany 26 - Switch No

32 Manual - Rinnai Condensing Water Heaters The conversion shall be carried out by a manufacturer’s authorized rep-resentative, in accordance with

Strany 27

Manual - Rinnai Condensing Water Heaters 33 Temperature Controller Installation • The controller should be out of reach of smal

Strany 28 - 60"

34 Manual - Rinnai Condensing Water Heaters Temperature Controller Installation 1. Determine a suitable location for the controll

Strany 29 - 12"

Manual - Rinnai Condensing Water Heaters 35 Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance doe

Strany 30 - Vertical Termination

36 Manual - Rinnai Condensing Water Heaters Technical Data Pressure Drop Curve Outlet Flow Data RC98 Water Fl

Strany 31

Manual - Rinnai Condensing Water Heaters 37 Space Heating If the water heater is to be used for both water (potable) heating

Strany 32 - CANADA ONLY

38 Manual - Rinnai Condensing Water Heaters Dimensions DIM DESCRIPTION RC80i in (mm) A Width 18.5 (470) B Depth 10.5 (266.

Strany 33

Manual - Rinnai Condensing Water Heaters 39 Ladder Diagram WATER LEVEL DETECTING CIRCUIT WATER LEVEL ELECTRODE TWIN THERMISTO

Strany 34

4 Manual - Rinnai Condensing Water Heaters WARNING Safety Behavior and Practices • Keep the area around the appliance clear

Strany 35 - Manual Valve

40 Manual - Rinnai Condensing Water Heaters NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licen

Strany 36 - Pressure Loss (psi) )

Manual - Rinnai Condensing Water Heaters 41 What is covered? This Warranty covers any defects in materials or workmanship when the product is inst

Strany 37

42 Manual - Rinnai Condensing Water Heaters What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is

Strany 38

Manuel – Rinnai Condensing Water Heaters 43 — Ne pas entreposer ni utiliser d'essence ou ni d'autres vapeurs ou liquides inflammables à

Strany 39

44 Manuel – Rinnai Condensing Water Heaters Comportements et pratiques de sécurité Réglage de température Instruction

Strany 40 - State Regulations

Manuel – Rinnai Condensing Water Heaters 45 Plages de température avec un contrôleur de température Ce chauffe-eau va tenter de fournir d

Strany 41 - Consumer Support

46 Manuel – Rinnai Condensing Water Heaters AVERTISSEMENT Coupez l'alimentation électrique, et fermez l'arrivée de gaz et d'eau

Strany 42

Manuel – Rinnai Condensing Water Heaters 47 Seuls des installateurs qualifiés avec une formation adéquate peuvent installer cet appareil. La garan

Strany 43 - Enregistrer votre produit à

48 Manuel – Rinnai Condensing Water Heaters to sideto frontto topto floor/ground Écartements par rapport à l'appareil 1. Ide

Strany 44 - Brûlure

Manuel – Rinnai Condensing Water Heaters 49 Installations à haute altitude Pour les installations de U.S., reportez-vous aux instr

Strany 45 - N° de micro‐

Manual - Rinnai Condensing Water Heaters 5 The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous

Strany 46 - AVERTISSEMENT

50 Manuel – Rinnai Condensing Water Heaters • Une vanne manuelle de coupure de gaz doit être placée sur la conduite d'alimentation en gaz en am

Strany 47 - Instructions d’installation

Manuel – Rinnai Condensing Water Heaters 51 Tuyauterie d'eau Valve à Bille / Valve de dégagement de pression Les soupapes

Strany 48

52 Manuel – Rinnai Condensing Water Heaters Tuyauterie d'eau • Une vanne manuelle de coupure d'eau doit intercalée sur

Strany 49

Manuel – Rinnai Condensing Water Heaters 53 GasSupply3/4"ColdWaterSupplyLine3/4" Hot Water Supply LineRinnaiEquipment ListRinnaiWater He

Strany 50

54 Manuel – Rinnai Condensing Water Heaters • Employez seulement le passage qui est approuvé et identifié comme acceptable pour les appareils de co

Strany 51

Manuel – Rinnai Condensing Water Heaters 55 Nombre de coudes à 90° 0 1 2 3 4 5 6 41 ft 1 (12.5 m) 35 ft 2 (10.7 m) 29 ft 3 (8.8 m) 23 ft

Strany 52

56 Manuel – Rinnai Condensing Water Heaters Contacts avec les constructeurs de ventilation pour des informations d'installation et de liste de

Strany 53

Manuel – Rinnai Condensing Water Heaters 57 Espacement pour terminaison de cheminée INSIDECORNER DETAI LFIXEDCLOSEDOPERABLEFIXEDCLOSEDOPERAB

Strany 54

58 Manuel – Rinnai Condensing Water Heaters Fixez la pièce de ventilation connectée sur le chauffe-eau avec une vis autotaraudeuse dans le trou situ

Strany 55

Manuel – Rinnai Condensing Water Heaters 59 Instructions d'utilisation À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ

Strany 56

6 Manual - Rinnai Condensing Water Heaters Temperature Controllers - Models MC-91-1US & MCC-91-1US The MC-91 controller is the st

Strany 57 - (ANS Z21.10.3, CSA 4.3)

60 Manuel – Rinnai Condensing Water Heaters Diagramme en escalier PHASE NEUTRE CONTACT DE DÉTECTION DE GEL FUSIBLE 7 A ANTI-FOUDRE

Strany 58

Manuel – Rinnai Condensing Water Heaters 61 Support à la clientèle Qu'est-ce qui est couvert ? Cette garantie couvre tous défauts dus aux ma

Strany 59

62 Manuel – Rinnai Condensing Water Heaters Que fait Rinnai pour exercer la garantie ? Rinnai va réparer ou remplacer le produit, ou toute partie o

Strany 60

Manual - Rinnai Condensing Water Heaters 63 Notes

Strany 61 - Support à la clientèle

© 2010 Rinnai America Corporation RC80, RC98 U290-665X03(00) Printed in Japan 11.01

Strany 62

Manual - Rinnai Condensing Water Heaters 7 How to Set the Temperature 1. If the water heater is off, press the ON/OFF button to t

Strany 63

8 Manual - Rinnai Condensing Water Heaters Suggested temperatures are • Kitchen 120 ºF (49º C) • Shower 98 - 110 ºF (37 - 43 ºC) • Bath Fill 1

Strany 64 - Printed in Japan 11.01

Manual - Rinnai Condensing Water Heaters 9 Using the Water Smart / Bath Fill Function Overview This function is exclusive to the BC-1

Příbuzné modely RC80I | RC80E |